Quality & transparency

Every lot, on the record.

Identity and purity are measured, documented and tied to the lot number printed on your vial. This is exactly what that paperwork looks like, and how to read it.

Helix & Co.
Certificate of analysisLot-matched report
Compound
Example peptide
Lot number
SPECIMEN-0001 1
Vial
10 mg · lyophilized
Methods
RP-HPLC · ESI-MS
Analysis date
YYYY-MM-DD
Storage
−20 °C · sealed · dark
Purity · RP-HPLC trace, UV 220 nm2
Identity · ESI mass spectrum3
Results4
Expected monoisotopic mass1000.0000 Da
Observed mass (from both charge states)…
Purity by RP-HPLC (peak area %)…
ResultCONFORMS
Authorized signature

Specimen for illustration only. Values are examples and not from a real lot. Your certificate carries your own lot’s measured results.

Anatomy of a COA

Four things to check, in this order.

1

The lot number

The link between your vial and its data. It must match the label on the vial exactly.

Matching a vial to its COA
2

The purity trace

One dominant peak, flat baseline. Purity is the main peak’s area as a share of all peak area.

Reading a chromatogram
3

The mass spectrum

Charge-state peaks convert back to a molecular weight, which confirms what the molecule is.

Confirming identity
4

The results table

Expected against observed, stated as numbers, with the methods and date alongside.

What’s on every COA

The testing standard

Four checks before a lot is released

Identity

Mass spectrometry confirms the molecular weight of the compound against the mass expected from its sequence.

ESI-MS

Purity

Reverse-phase HPLC reports the percentage of target peptide in the vial.

RP-HPLC

Appearance & fill

Visual and gravimetric checks on the finished vials.

Visual · gravimetric

Lot-matched report

The certificate is tied to the lot number printed on your vial and sent on request.

Email the lot number

On every certificate

Numbers, not tick boxes

Lot number

Ties the report to the physical vial in your hands.

SPECIMEN-0001

Compound & vial size

Name, quantity and form, so nothing is ambiguous.

10 mg · lyophilized

Methods used

Which techniques produced the data, so you can judge it.

RP-HPLC · ESI-MS

Expected vs observed mass

Identity shown as measured values you can check yourself.

M(exp) · M(obs) · Δ ppm

Purity

The share of the main peak across the whole trace.

area % by HPLC

Date & storage

When it was measured and how to keep it stable.

−20 °C · sealed · dark

Verify your vial

Three steps, two minutes

Read the label

Note the lot number exactly as printed, including letters and dashes.

Worked example →

Request the report

Email us the lot number. We reply within 1 business day with the matching COA.

Email us →

Compare

Check lot, compound, mass and purity against your vial. If anything differs, don’t use it and contact us.

All worked examples →

Holding a vial from us?

Ask for its certificate. Storage guidance is in our handling guide.

Request a COA